Tool Chronicle

On the record

clunk.repair

Read 2 times since 11 Oct 2026. Last read 12 Oct 2026.

8

tools offered to AI agents, on the record.

https://clunk.repair/

Last change
None yetUnchanged since first read.
Declared read-only
2 of 8
llms.txt
None

Tools

8 live
  1. find_compatible_partDoes not say

    When find_compatible_part appears in nextTools, resolve the completed observations to one evidence-bounded outcome: no part needed, exact verified part, complete product code required, or professional diagnosis required. Exact outcomes may include a Shopify UCP handoff for live offers; accept only the exact part number Clunk returns.

    First seen 11 Oct 2026. Unchanged since.

  2. get_repair_stateReads only

    Read the complete current catalog task or diagnosis step, including bounded observation choices and the tools available next.

    First seen 11 Oct 2026. Unchanged since.

  3. record_observationDoes not say

    When record_observation appears in nextTools, record task.currentCheck.checkId and one listed resultId explicitly reported by the human. Never infer a physical observation. Hazard results stop the workflow immediately.

    First seen 11 Oct 2026. Unchanged since.

  4. search_supported_appliancesReads only

    Search Clunk's visible source-backed catalog by appliance kind, brand, full/partial model text, or observable problem. Results include capability and ambiguity guidance. If the person cannot find the number, read modelNumberHandoff, ask them to inspect the common label locations, and reject serial text rather than guessing a suffix.

    First seen 11 Oct 2026. Unchanged since.

  5. select_applianceDoes not say

    Select an applianceId returned by catalog search. Include productCode only when the human read the complete model value from the label. symptomId binds the selection to a supported problem when search did not already filter by one.

    First seen 11 Oct 2026. Unchanged since.

  6. show_componentDoes not say

    When show_component appears in nextTools, focus a componentId from the current repair state in the shared diagram so the human can inspect the correct visible location.

    First seen 11 Oct 2026. Unchanged since.

  7. start_diagnosisDoes not say

    When start_diagnosis appears in nextTools, begin the already-selected model and problem at its safety check. Call select_appliance first; this tool does not choose or change the problem.

    First seen 11 Oct 2026. Unchanged since.

  8. stop_and_escalateDoes not say

    End the diagnosis at a safety or evidence boundary and show professional-service guidance. Use immediately for reported hazards or unsafe access.

    First seen 11 Oct 2026. Unchanged since.

Run this site? This page shows what your site told our crawler, ToolChronicleBot. To be left out, disallow it in robots.txt or write to hello@toolchronicle.com.